A data centre fails quietly: a breaker warming up, a chiller valve drifting, a generator room a few degrees hotter than last week. WOLKER runs the same inspection round on a schedule with a quadruped robot, puts a thermal reading on every panel and sends the findings into the system your operators already watch. Report within 48 hours. Proof of concept from AED 18,500.
Runs on a DEEP Robotics quadruped — X30 Pro or Lynx M20, carrying the sensing pack — thermal PTZ, acoustic, gas, RTK. Authorised DEEP Robotics distributor in the UAE.
Ask about data centre roundsReplies on WhatsApp, same day
What the round covers
Data halls: hot and cold aisle temperatures by rack row, thermal image of every distribution panel and busway tap-off, visual check of leak-detection tape and raised-floor tiles.
Electrical rooms: switchgear and UPS cabinets by thermal camera, acoustic check for partial discharge and loose connections, battery room temperature profile.
Mechanical plant: chillers, pumps, CRAC/CRAH units — bearing and motor temperatures, valve positions, visible leaks, water on the floor.
Generator and fuel yard: engine block and exhaust temperatures after a test run, coolant and fuel line leaks, enclosure doors and fans.
The route is fixed once with your operations team and then repeats the same way, so readings are comparable from round to round.
Into your systems, not into a PDF
Findings carry location, timestamp, reading and the evidence frame. They can be delivered as a signed report, as a feed into your BMS, DCIM or CMMS through an HTTP API, or both. Threshold breaches can raise a ticket or an alarm on the operator screen; see integration.
The mission system runs on the robot itself. Images and readings stay on your network; nothing is uploaded to a third-party cloud. Access for our engineers is through your rules — VPN, escorted laptop or none at all.
Security requirements such as visitor induction, escort, no-photo zones and data handling are agreed in writing before the first round and listed in the report.
Start with a proof of concept
Day one: route walk with your team, mapping, first full round. Day two: second round, comparison, hand-over of the report and the data sample in your format. From AED 18,500; the amount is credited against a service contract or a purchase within 90 days.
A four-week pilot with rounds on your schedule, integration into one system and a written evaluation is about AED 75,000. Details on POC and pilot.
What we need from you: access and induction for one operator, a route of up to about 3 km per round, a 230 V socket for the dock, and a contact who signs the evaluation criteria.
What you get after each round
A thermal image and a plain photo for every point on the route, with the previous round beside it.
A list of exceptions ranked by temperature rise or by your thresholds, each with location and recommended check.
A hash-sealed report, so an auditor or an insurer can confirm later that nothing was edited after the round.
Trend lines per asset once three rounds exist — the point at which a drifting chiller or a warming breaker becomes visible before it alarms.
Next step
Send the location, the rooms or zones, and what your checklist asks for; we reply with a scope and a date. Ask about data centre rounds
Updated 15 November 2026. Prices in AED exclude 5% UAE VAT and cover sites within the UAE.